top of page
PB 21.jpg

RefleX T238 UV Chambers

For ultrapure water disinfection

RefleX T238 UV Disinfection Chambers 

NTA%20WEB%20640%202%20COL238%20_edited.j

An essential component in advanced oxidation processes and water disinfection, RefleX UV Chambers use patented technology to reflect 99.8% of 254 nm UV generated back into the chamber flow. 

 

With a 75% smaller footprint than standard UV systems and 38” high-output lamps, RefleX T238 UV Chambers provide highly efficient performance with the lowest cost service schedule of any low or medium pressure UV system available.

 

Take command of more in less space.

 

RefleX Controllers provide the information you need at a glance – with the ability to control up to four treatment chambers independently from a simple menu.

  • Compact footprint

  • Vertical or horizontal mount

  • Fewer lamps

  • Up to 75% less energy use

  • 120V or 230V single phase power

  • No flow, no problem

  • Real-time dosimetry

  • NSF 50 and NSF 61 certification

  • No-tool lamp change

  • TUV safety certified

nta web 320 1 col control box  .jpg

Control up to four chambers

from a tidy 8X9X4” footprint.

Flow Rate:
20 (4.5) gpm (m3/hr.) 

Lamps:
One high-output
amalgam lamp

Power:
240 watts with

control box

Maximum UV Penetration

The NeoTech T238™ provides users an unparalleled level of engineering sophistication by maximizing UV distribution in a patented 99% reflective chamber.

 

This unique technical advantage also reduces the number of lamps and power requirements by up to 90% compared to standard UV systems.

Minimal Maintenance

The service and maintenance for

RefleX UV Chambers have three

basic requirements:

 

Lamp Replacement:

No tools needed

 

UV Monitor:

Changed out with screwdriver

during operation

 

Cleaning:

May be cleaned as needed in

a CIP loop or manually brushed.

1 col icon ruler  .jpg

Get the specs

 

Everything you need to know

DOWNLOAD >

1 col icon guage.jpg

Let us help size
your system
solution

Start smart

BY THE NUMBERS >

Industry Application Requirements

Industry Application

Requirements
 

Get them all by the numbers

REVIEW >

Screen Shot 2021-01-04 at 4.46.11 PM.png

Specifications:

Screen Shot 2021-01-04 at 4.48.18 PM.png

^ At rated pressure drop.

* Lamp life is based on a maximum of one on-off cycle per day and room temperature water.

+ All units come standard with sanitary tri -clamp fittings for improved reliability, sanitation, and ease of

installation. Alternative connections are available upon request.

Unparalleled Efficiency.

The NeoTech T238™ boasts the smallest footprint in its class. With as few as one-tenth as many bulbs compared to standard UV systems, it has the lowest operating cost and maintenance schedule in the field.

Options and Spares:

Screen Shot 2020-11-28 at 11.26.11 AM.pn

Higher reflectivity for higher transmissivity.

The UV transmissivity (UVT) of the treated water, combined with the flow rate through the unit, determine the UV dosage applied to the water. Particles in water typically absorb or reflect UV light which affects the water's UV transmissivity. NeoTech Aqua’s units are rated based on a UVT of 95%. The above graph illustrates the appropriate rating for the T238 based on varying UVT levels. The NeoTech Aqua Solutions technical team provides complimentary UVT analysis on customer-supplied water samples to ensure proper UV equipment sizing.  Let us help >